Design
The system allows for design flexibility, from the simplest to the
most complex. It also provides for ducted or ductless systems,
including virtually any application (or a variety of applications)
within a single building. With the wide range of products available
in our combined Mr. Slim and CITY MULTI product lines, your design
can connect 1 to 50 indoor units to a single outdoor unit.
Many products use T-branches and
headers for the ultimate in piping design flexibility. Modular
systems with a variety of indoor and outdoor units can be put
together for a system that is just right for your needs.
• Condensing Units (heat recovery, heat pump and water-sourced)
offer vertical air discharge that allows units to be installed
side-by-side in a single area, saving space and resources. They
also offer long line lengths - up to 2,624 feet on R2 Series and
3,280 on Y-series (one way). Additionally, you don't need space for
compressor farms because the mechanical chases take up very little
space.
• Indoor units meet your design and space needs - ducted or
ductless, ceiling, floor, wall or vertical.
Install
Installation includes simple two-pipe systems with easy,
non-polar, two-wire control connections. This means less labor and
fewer materials as well as quicker, easier installation. Copper
refrigerant piping is smaller and lighter than ductwork or Schedule
40 steel water pipes, so the modular outdoor unit's compact design
also simplifies transportation.
Maintain / Service
Many other systems require retro-commissioning and constant
maintenance to preserve their installed efficiency, but VRF
technology has all the logic built in. System performance is
constantly modified to maximize performance and comfort. System
tests are available to check wiring, sensor and the refrigerant
levels. Normal maintenance consists of changing filters and
cleaning coils. Many systems allow an indoor unit to be serviced
while other indoor units within the same piping system are still in
operation. VRF technology also allows for lower maintenance costs
than water-cooled chillers since water treatment issues are
avoided.
System Simplicity – Design, Install, Maintain
Design
The system allows for design flexibility, from the simplest to the
most complex. It also provides for ducted or ductless systems,
including virtually any application (or a variety of applications)
within a single building. With the wide range of products available
in our combined Mr. Slim and CITY MULTI product lines, your design
can connect 1 to 50 indoor units to a single outdoor unit.
Many products use T-branches and
headers for the ultimate in piping design flexibility. Modular
systems with a variety of indoor and outdoor units can be put
together for a system that is just right for your needs.
• Condensing Units (heat recovery, heat pump and water-sourced)
offer vertical air discharge that allows units to be installed
side-by-side in a single area, saving space and resources. They
also offer long line lengths - up to 2,624 feet on R2 Series and
3,280 on Y-series (one way). Additionally, you don't need space for
compressor farms because the mechanical chases take up very little
space.
• Indoor units meet your design and space needs - ducted or
ductless, ceiling, floor, wall or vertical.
Install
Installation includes simple two-pipe systems with easy,
non-polar, two-wire control connections. This means less labor and
fewer materials as well as quicker, easier installation. Copper
refrigerant piping is smaller and lighter than ductwork or Schedule
40 steel water pipes, so the modular outdoor unit's compact design
also simplifies transportation.
Maintain / Service
Many other systems require retro-commissioning and constant
maintenance to preserve their installed efficiency, but VRF
technology has all the logic built in. System performance is
constantly modified to maximize performance and comfort. System
tests are available to check wiring, sensor and the refrigerant
levels. Normal maintenance consists of changing filters and
cleaning coils. Many systems allow an indoor unit to be serviced
while other indoor units within the same piping system are still in
operation. VRF technology also allows for lower maintenance costs
than water-cooled chillers since water treatment issues are
avoided.